100% FREE NS0-093–100% FREE NEW DUMPS | HIGH HIT-RATE TEST NETAPP ACCREDITED HARDWARE SUPPORT ENGINEER TUTORIALS

100% Free NS0-093–100% Free New Dumps | High Hit-Rate Test NetApp Accredited Hardware Support Engineer Tutorials

100% Free NS0-093–100% Free New Dumps | High Hit-Rate Test NetApp Accredited Hardware Support Engineer Tutorials

Blog Article

Tags: New NS0-093 Dumps, Test NS0-093 Tutorials, Test NS0-093 Objectives Pdf, NS0-093 Latest Exam Cost, Learning NS0-093 Mode

Our company according to the situation reform on conception, question types, designers training and so on. Our latest NS0-093 exam torrent was designed by many experts and professors. You will have the chance to learn about the demo for if you decide to use our NS0-093 quiz prep. We can sure that it is very significant for you to be aware of the different text types and how best to approach them by demo. At the same time, our NS0-093 Quiz torrent has summarized some features and rules of the cloze test to help customers successfully pass their NS0-093 exams.

Network Appliance NS0-093 exam encompasses a variety of topics, including NetApp FAS architecture, cluster mode fundamentals, disk and aggregate management, and data protection technologies. NetApp Accredited Hardware Support Engineer certification exam focuses on evaluating the ability of a candidate to install, configure, and maintain NetApp storage systems, troubleshoot performance issues, provide technical support, and ensure successful operations.

Network Appliance NS0-093 Exam is designed to test the knowledge and skills of hardware support engineers who work with NetApp storage systems. NetApp Accredited Hardware Support Engineer certification program is an industry-recognized benchmark that signifies an individual’s proficiency in providing hardware support for NetApp storage solutions.

>> New NS0-093 Dumps <<

Board Your Capacities By Updated Network Appliance NS0-093 Exam Dumps

It is quite clear that most candidates are at their first try, therefore, in order to let you have a general idea about our NS0-093 test engine, we have prepared the free demo in our website. The contents in our free demo are part of the real materials in our NS0-093 study engine. Just like the old saying goes "True blue will never strain" You are really welcomed to download the free demo in our website to have the firsthand experience, and then you will find out the unique charm of our NS0-093 Actual Exam by yourself.

Network Appliance NS0-093 (NetApp Accredited Hardware Support Engineer) Exam is a certification exam that is designed to test the knowledge and skills of hardware support engineers who work with NetApp storage systems. NS0-093 Exam is an industry-recognized certification that demonstrates a candidate's expertise in supporting NetApp storage systems, including installation, configuration, and troubleshooting.

Network Appliance NetApp Accredited Hardware Support Engineer Sample Questions (Q45-Q50):

NEW QUESTION # 45
A node has panicked with a PCI/NMI error. Giveback has not been performed.
Which two commands should you run to collect the logs to determine the cause? (Choose two.)

  • A. event log show
  • B. pelog -a -g=2
  • C. rdfile /mroot/etc/log/SSRAM
  • D. show pci -v

Answer: B,C

Explanation:
To diagnose a PCI/NMI error and collect logs, use the following commands:
* What it does:This command collects PCI error logs, including detailed information about PCI devices and the errors that caused the panic.
* How to use:Run the command from the nodeshell to capture the required PCI log entries.
1. pelog -a -g=2
* What it does:This command reads the SSRAM log file, which contains low-level error information related to PCI and other hardware subsystems.
* How to use:Run the command to view the log entries directly for detailed troubleshooting.
2. rdfile /mroot/etc/log/SSRAM
* B. show pci -v:
* While this command displays PCI device information, it does not provide detailed error logs.
* D. event log show:
* This displays event log entries but does not contain the specific PCI or NMI-related logs required for diagnosing the panic.
Why Other Options Are Incorrect:
* "ONTAP Hardware Troubleshooting Guide" lists pelog and SSRAM as tools for analyzing PCI errors.
* "ONTAP Panic Analysis Guide" emphasizes the importance of collecting detailed hardware logs.
References:


NEW QUESTION # 46
On an AFF A700 system, a SAS stack is connected to SAS ports 2a and 2b. The system has an additional 4- port SAS card in slot 9.
How should the cabling the corrected for best practices?

  • A. Use port 2b and 9d.
  • B. Use port 2a and 2c.
  • C. Use port 2a and 9b.
  • D. Use port 2a and 9a.

Answer: D


NEW QUESTION # 47
Which three commands can be used to manually generate a kernel core file? (Choose three.)

  • A. ::> reboot -node <node_name> -dump true
  • B. SP> system power cycle
  • C. SP> system core
  • D. ::> halt -dump true -node <node_name>
  • E. ::> system node panic -node <node_name>

Answer: A,D,E

Explanation:
To manually generate a kernel core file in ONTAP, the following commands can be used:
* What it does:Reboots the specified node and generates a core dump before rebooting.
* Example Usage:
1. ::> reboot -node <node_name> -dump truereboot -node <node_name> -dump true
* What it does:Halts the specified node and generates a core dump before shutting down.
* Example Usage:
2. ::> halt -dump true -node <node_name>halt -dump true -node <node_name>
* What it does:Forces a panic on the specified node, which triggers a kernel core dump.
* Example Usage:
3. ::> system node panic -node <node_name>system node panic -node <node_name>
* A. SP> system power cycle:
* This command reboots the system from the Service Processor but does not generate a core dump.
* E. SP> system core:
* This command displays core file information but does not generate a new core dump.
Why Other Options Are Incorrect:
* NetApp "Kernel Core Dump Guide" explains the use of reboot, halt, and panic commands to trigger core dumps.
* ONTAP CLI Reference includes the syntax for these commands.
References:


NEW QUESTION # 48
On a NetApp FAS9000 system, which two field replaceable units (FRUs) are supported for replacement without takeover? (Choose two.)

  • A. caching module
  • B. NVRAM module
  • C. I/O module
  • D. DCPM module

Answer: B,C

Explanation:
FRUs on FAS9000 Supporting Replacement Without Takeover:
* A (I/O Module): I/O modules can be replaced hot (without takeover) to maintain system uptime during hardware servicing.
* D (NVRAM Module): NVRAM modules on FAS9000 can also be replaced without a node takeover, ensuring data integrity during replacement.
Why Other Options Are Incorrect:
* B (DCPM Module): The DCPM (Data Center Power Management) module is not hot-swappable and requires a node takeover.
* C (Caching Module): The caching module is integrated and typically requires a node takeover or power-down for replacement.
NetApp Reference Documentation:
* Refer to the "NetApp FAS9000 Hardware Service Guide" for supported FRU replacement procedures and operational constraints.


NEW QUESTION # 49
When you add a new disk to an ONTAP 9.1 system, you see an error that the disk "has raid label with version (16), which is not within the currently supported range (14-15)." What is one possible cause of this error?

  • A. The disk is a non-zeroed spare.
  • B. The disk needs to be assigned to the new system.
  • C. The disk was in a system with a newer version of ONTAP software
  • D. The disk firmware is too new for ONTAP software.

Answer: C

Explanation:
Explanation of RAID Label Versions:
* Disks in ONTAP systems contain metadata known as RAID labels. These labels store critical information such as ownership, aggregate membership, and versioning.
* The error indicates a mismatch between the RAID label version on the disk and the supported versions of the ONTAP system.
Why Option D Is Correct:
* If a disk has a RAID label created by a newer version of ONTAP (e.g., version 16) and is then inserted into a system running an older version of ONTAP (e.g., supporting versions 14-15), the label will not be recognized.
* This mismatch causes ONTAP to reject the disk.
Resolution:
* Upgrade the ONTAP version to match the RAID label on the disk.
* Alternatively, zero the disk to reset its RAID label, but this will erase all data on the disk.
NetApp Reference Documentation:
* The "ONTAP Disk Management Guide" and "ONTAP Compatibility Matrix" explain RAID label versions and compatibility issues when moving disks between ONTAP systems.


NEW QUESTION # 50
......

Test NS0-093 Tutorials: https://www.briandumpsprep.com/NS0-093-prep-exam-braindumps.html

Report this page